APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5466 Issued:2010-11-11
Revised:2014-03-07
Style 5466 Single Conductor with Other-Than-Extruded Insulation

Rating200 deg C, 1000 Vac, Horizontal flame.
Conductor30 AWG - 20 AWG, solid or stranded.
InsulationInner insulation - Sintered polyimide (PI) tape, 2.0 mils minimum average thickness, 1.8 mils minimum thickness at any point. Outer insulation - Sintered polyimide (PI) tape, 1.0 mils minimum average thickness, 0.9 mils minimum thickness at any point. Coating - FEP or MFA, 0.5 mils minimum average thickness, 0.4 mil minimum thickness at any point.
AssemblyInner insulation, covered by Outer insulation, covered by Coating.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024