APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5470 Issued:2011-05-06
Revised:2019-05-13
Style 5470 Single Conductor with non-extruded insulation.

Rating450 deg C, 2000 Vac Horizontal flame.
Conductor24 AWG - 8 AWG, Solid or Stranded.
InsulationMica Tape, 75 mils minimum average thickness of total Mica tape layers, 68 mils minimum thickness at any point of total Mica tape layers and a Treated Glass Braid, 5 mils minimum average thickness, applied over the Mica Tape.
ShieldOptional Braided Shield, may be applied over the Insulation.
CoveringOptional Inner Covering, PTFE Tape layer may be applied between the Mica Tape and the Treated Glass Braid.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring where not subjected to movement or mechanical abuse after installation.