APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5476 Issued:2012-02-09
Revised:2019-05-13
Style 5476 Single or multiple conductor with other-than-extruded insulation

Rating450 deg C, 600 Vac, Horizontal flame.
Conductor30 AWG - 4/0 AWG, solid or stranded
InsulationMica Tape with Glass Braid
Minimum Average Thickness
Total Mica tape layers30-12 AWG17 mils
Total Mica tape layers11-4 AWG21 mils
Total Mica tape layers3-4/0 AWG26 mils
Glass braid treated with silicone varnish or TFE finish30-12 AWG7 mils
Glass braid treated with silicone varnish or TFE finish11-4 AWG15 mils
Glass braid treated with silicone varnish or TFE finish3-4/0 AWG20 mils
BinderOptional - May be applied between Mica Tape and Glass Braid. See facing page for material detail.
AssemblyOptional - Two or more conductors described above, may be cabled together with a maximum overall diameter of 1.500 inches. A mica glass binder and/or fiberglass fillers may be employed. The assembly may have an overall treated glass braid.
ShieldOptional - 36-30 AWG Type "A" Nickel or 27 percent minimum nickel coated copper.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring where not subjected to repeated flexing and protected from mechanical abuse, and where the acceptability, including current-carrying capacity, has been determined by UL, LLC.