APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5487 Issued:2012-04-10
Revised:2013-09-17
Style 5487 Single conductor with non-extruded insulation

Rating180 deg C, 300 Vac, Horizontal Flame.
Conductor44 AWG - 10 AWG, solid or stranded.
SeparatorOptional - Non-Extruded Foamed PTFE or Non-Extruded PTFE, 2 mils minimum average thickness, 1.5 mils minimum at any point.
InsulationNon-extruded tape wrapped PEEK, 4 mils minimum average thickness, 3 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring where not subject to mechanical abuse.

UL and the UL Logo are trademarks of UL LLC © 2025