APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5491 Issued:2012-04-10
Revised:2021-08-19
Style 5491 Single conductor with non-extruded insulation

Rating250 deg C, 50 Vac, Horizontal Flame.
Conductor44 AWG - 10 AWG, solid or stranded.
InsulationTape wrapped Non-extruded Thermoplastic Fluoropolymer insulation, 1.0 mils minimum average thickness, 0.8 mils minimum thickness at any point. See Facing Page for compound designation.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring where not subject to mechanical abuse.

UL and the UL Logo are trademarks of UL LLC © 2025