APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5549 Issued:2015-01-13
Revised:2015-01-28
Style 5549 Single conductor with other-than-extruded insulation

Rating125 deg C, 600 Vac.
Conductor20 AWG - 10 AWG, consisting of 29-23 AWG stranding.
InsulationNonextruded Polyethylene Terephthalate tape, minimum average 0.5 mil thick, applied with half lap between inner and outer closely woven polyethylene terephthalate fiber or polyester braids, alternate - outer braid may be Aramid fiber.
AssemblyInsulated single conductor.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseLead wire within Hermetically Sealed Motors where the acceptability of the combination is to be determined by Underwriters Laboratories Inc.

UL and the UL Logo are trademarks of UL LLC © 2024