Rating | 125 deg C,no voltage specified, Horizontal flame. |
|
Conductor | 50 AWG - 2 AWG, solid or stranded. |
|
Insulation | Polyester Tape, No.50-16 AWG; 5.5 mils minimum average thickness and 5.0 mils minimum at any point. No.15-2 AWG; 8.0 mils minimum average thicknes and 7.0 mils minimum thickness at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring. |
|