APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5554 Issued:2015-07-27
Revised:New
Style 5554 Laminated flat ribbon cable with overlap shield.

Rating105 deg C, 300 Vac, Horizontal flame.
Conductor32 AWG - 10 AWG, flat, straight or irregular parallel in one plane.
InsulationPET film, 1.2 mils minimum thickness bonded on each side of conductors with polyester adhesive, 1.2 mils minimum thickness. 16 mils minimum edge width and 16 mils minimum distance between conductors.
Assembly2 - 150 conductors, laid parallel.
ShieldMetal faced polyester tape with polyester adhesive, total 0.5 mils minimum thickness, wrapped over insulated laminated cable longitudinally with 84 mils minimum overlap distance.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.