APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5559 Issued:2016-08-24
Revised:New
Style 5559 Laminated Non-Extruded Flat Ribbon Cable

Rating80 deg C,90 Vac Horizontal flame.
Conductor50 AWG - 12 AWG, flat or round, Straight or irregular parallel in one plane.
InsulationPET film, 0.8 mils minimum thickness, with 0.8 mils minimum flame retardant polyethylene adhesive on each side of conductors laminated together. 11 mils minimum edge width and 8 mils minimum distance between conductors.
Assembly2 to 150 conductors, laid parallel, laminated.
ShieldMetal faced polyester tape with polyester adhesive, total 0.7 mils minimum thickness, laminated on one or both sides of PET film insulation entirely.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.