APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5561 Issued:2016-11-30
Revised:New
Style 5561 Single conductor with other-than-extruded insulation

Rating550 deg C,300 Vac, Horizontal flame.
Conductor24 AWG - 4 AWG solid or stranded round, Copper, nickel-coated, Type A, 27 percent minimum nickel coated copper. Nickel, alloy. Nickel-chromium alloy.
InsulationComposite construction consisting of mica insulation covered by a treated fiberglass braid
24-12 AWG conductor size25 mils min average22 mils minimum at any point
11-4 AWG33 avg30 min
ShieldOptional. stainless steel, alloy 304, applied as a braid over the treated glass braid.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring where not subject to movement after installation.