APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5561 Issued:2016-11-30
Revised:2020-05-28
Style 5561 Single conductor with other-than-extruded insulation

Rating550 deg C,300 Vac, Horizontal flame.
Conductor24 AWG - 4 AWG solid or stranded round, Copper, nickel-coated, Type A, 27 percent minimum nickel coated copper. Nickel, alloy. Nickel-chromium alloy.
InsulationComposite construction consisting of mica insulation covered by a treated fiberglass braid
AWG Conductor SizeMinimum average thickness (mils)Minimum thickness at any point (mils)
24-122522
11-43330
ShieldOptional. stainless steel, alloy 304, applied as a braid over the treated glass braid.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring where not subject to movement after installation.

UL and the UL Logo are trademarks of UL LLC © 2025