APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5565 Issued:2016-12-16
Revised:2016-12-25
Style 5565 Laminated Non-Extruded Flat Ribbon Cable

Rating105 deg C, 90 Vac, Horizontal flame.
Conductor50 AWG - 12 AWG, flat or round, Straight or irregular parallel in one plane.
InsulationPETP film, 0.8 mils minimum thickness, with 0.8 mils minimum flame retardant polyolefin (FRPO) adhesive on each side of conductors laminated together. 12 mils minimum edge width and 8 mils minimum distance between conductors. See Facing Page.
Assembly2 to 150 conductors, laid parallel, laminated.
ShieldMetal faced polyester tape with polyester adhesive, total 0.6 mils minimum thickness, wrapped over insulated laminated cable with minimum 5% overwrapped portion.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024