APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5566 Issued:2017-03-03
Revised:New
Style 5566 Single Conductor with Non-Extruded Insulation

Rating200 deg C, 600 Vac, Horizontal Flame.
Conductor50 AWG - 24 AWG, Stranded Metal Coated.
InsulationNon-Extruded consists of below layers which are heat sealed and tape wrapped.
Materialmils min avg thicknessmils min thickness at any point
PI3.53
PTFE4.54
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.