APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5573 Issued:2018-10-12
Revised:2018-10-16
Style 5573 Multiple-conductor cable with optical fiber using non-integral jacket

Rating80 deg C,30 Vac, Horizontal flame.
Fiber OpticGlass fiber or plastic fiber, 8 mils minimum diameter, 20 mils maximum diameter.
CoveringExtruded TPE covering with minimum average 5 mils thickness and minimum thickness at any point 4 mils
Insulated ConductorLabeled or complying with manufacturer's AWM procedure.
AssemblyOne or more optical fiber members with TPE covering together with overall TPE jacket. Two or more insulated conductors shall be employed within the jacket. Fillers and/or binder tapes may be employes.
ShieldOptional.
JacketExtruded TPE with minimum average thickness 10 mils, minimum thickness at any point 8 mils.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring

UL and the UL Logo are trademarks of UL LLC © 2024