Rating | 80 deg C,30 Vac VW-1 flame, Cable flame. |
|
Fiber Optic | Glass fiber or plastic fiber, 8 mils minimum diameter, 20 mils maximum diameter. |
|
Covering | Extruded TPE covering with minimum average 5 mils thickness and minimum thickness at any point 4 mils |
|
Insulated Conductor | Labeled or complying with manufacturer's AWM procedure. |
|
Assembly | One or more optical fiber members with TPE covering together with overall TPE jacket. Two or more insulated conductors shall be employed within the jacket. Fillers and/or binder tapes may be employed. |
|
Shield | Optional |
|
Jacket | Extruded TPE |
| Diameter of core assembly under jacket | Minimum average thickness | Minimum thickness at any point |
| 1.500 or less inch | 10 mils | 8 mils |
| 1.501-2.500 inch | 15 mils | 12 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External interconnection of Class 2 circuits |
|