Rating | 80 deg C, 90 Vac, Horizontal flame. |
|
Conductor | 50 AWG - 12 AWG, flat or round, Straight or irregular parallel in one plane. |
|
Insulation | Any material in table 7.1 of UL758 rated 80 deg C, See facing page for details. Film(including adhesive), 5 mils minimum thickness on each side of conductors laminated together. 4 mils minimum edge width and 4 mils minimum distance between conductors. |
|
Assembly | 2 to 150 conductors, laid parallel, laminated. |
|
Shield | Metal clad Polyester Tape 0.6 mils minimum thickness, with minimum 0.16 inch overwrapped portion. |
|
Covering | PET film, 0.3 mils minimum thickness, with 0.9 mils minimum flame retardant polyoester adhesive on each side of shield laminated together with minimum 0.0100 inch overwrapped portion of each side of end. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring. |
|