APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5575 Issued:2019-07-25
Revised:2019-07-26
Style 5575 Laminated Non-Extruded Flat Ribbon Cable

Rating80 deg C, 90 Vac, Horizontal flame.
Conductor50 AWG - 12 AWG, flat or round, Straight or irregular parallel in one plane.
InsulationAny material in table 7.1 of UL758 rated 80 deg C, See facing page for details. Film(including adhesive), 5 mils minimum thickness on each side of conductors laminated together. 4 mils minimum edge width and 4 mils minimum distance between conductors.
Assembly2 to 150 conductors, laid parallel, laminated.
ShieldMetal clad Polyester Tape 0.6 mils minimum thickness, with minimum 0.16 inch overwrapped portion.
CoveringPET film, 0.3 mils minimum thickness, with 0.9 mils minimum flame retardant polyoester adhesive on each side of shield laminated together with minimum 0.0100 inch overwrapped portion of each side of end.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.