APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5583 Issued:2020-08-11
Revised:2020-08-10
Style 5583 Single conductor with other-than-extruded insulation

Rating90 deg C, 30 Vac, Horizontal flame.
Conductor50 AWG minimum , Solid or Stranded.
InsulationPETP tape with Polyester adhesive, 0.3 mils minimum average thickness, 0.2 mils minimum thickness at any point.
AssemblyOriented Polyethylene Terephthalate tape spirally wrapped with Polyester adhesive.
CoveringOptional, PETP tape with Polyester adhesive, 0.3 mils minimum average thickness, 0.2 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.