APPLIANCE WIRING MATERIAL
Subj.758 Section 5 Page 5586 Issued:2021-10-26
Revised:New
Style 5586 Multi-Conductor Cable Using Non-Integral Jacket

Rating200 deg C, no voltage specified, Horizontal flame.
Insulated ConductorLabeled or complies with manufacturer's AWM Procedure.
AssemblyTwo or more singles or groups of twisted singles twisted together. Lay not specified. Barrier layer, shield, braid and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
SeparatorOptional, non-extruded Foamed PTFE or non-extruded PTFE.
ShieldOptional, may be over one or more of the insulated conductors or applied over the assembly.
JacketTape wrapped Non-extruded Thermoplastic Fluoropolymer, minimum average thickness 4 mils, minimum thickness at any point 3 mils. See Facing Page for compound.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2025