Rating | 200 deg C, 600 Vac, Horizontal flame. |
|
Insulation | Labeled or complying with Manufacture's AWM Procedure. |
|
Assembly | Two or more insulated conductors, each with a fiberglass braid (inner covering), cabled together into a round cable. There shall be an inner shield, binder tape(s) and (optional) fillers, an outer non-extruded fiberglass braid and an optional overall metal braid, as described below. |
|
Inner Covering | Non-extruded fiberglass braid with 6 mils minimum average thickness, 5 mils minimum thickness at any point, provided over each insulated conductor. |
|
Inner Shield | Metallic braid or tape provided over the cable core. |
|
Binder | One or more non extruded PTFE tapes provided over the inner shield. |
|
Outer Covering | Non-extruded fiberglass braid with 18 mils minimum average thickness and 17 mils minimum thickness at any point, provided over the |
|
Outer Braid | Optional - Stainless steel braid |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring of Electronic Equipment or Appliances for Equipment Interconnection |
|