|
Rating | 150 deg C, 600 Vac, Horizontal flame. |
|
Insulated Conductor | Labeled or complying with manufacturer's AWM Procedure. |
|
Shield | Optional. |
|
Assembly | Core assemblies, laid parallel, laminated with covering to form a flat cable construction, maximum cable width 5.2 inch. Each core assembly consists of non-shielded or shielded, PTFE tapes or foamed PTFE tapes wrapped over a labeled insulated conductor or labeled insulated conductors. Barrier layer, tapes and/or fillers are optional. May use same or mixed AWG sizes. Manufacturer shall maintain a complete description of each assembly. |
|
Covering | Non-separable heat-sealed 4 layers of tapes (See Facing Page in details of material and thickness for each layer), 9 mils minimum thickness of total composite 4 layers on each side of core assemblies laminated together with 29 mils minimum edge width (in left and right side) of covering and 21 mils minimum distance between each core assembly if any distance between each assembly. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring. |
|