Electrical Insulation System Components E200050
P LEO & CO LTD
UNIT 210, 2nd FLOOR, BUILDING 8W PHASE TWO, HONG KONG SCIENCE PARK, PAK SHEK KOK, NT HK
System Component System Designation System Class
1A025, 1G006, 1G015, 1G027A, 1G130 (o), 1G155, 1G180, 1H818 (m), 1H860 (f), 1H866 (g), 1H86A (o), 1H86R (g), 1K063, 1K063CR, 1K7170, 1K7171A, 1K7172, 1K7270, 1N008, 1N012, 1P130, 1P133 (f), 1P350 (e), 1P700 (b), 1P701 (b), 1P702 (b), 1P703, 1P705, 1P707 (b), 1P751, 1P800, 1P801, 1P802, 1P802 (k), 1P808, 1P830, 1P833 xx (@), 1PEN2, 1PEN3, 1PN2R, 1PN3R, 2T-TFL-xx.x (a), 2T-TFS-xx.x (a), 2T-TFT-xx.x (a), 8M81, D/PEN**, DM**, DMD###, DPD###, L/PEN/L*&*, N###/1N012(**), N###/N155(**), N###/OL50(**), N###/PEN*&*, N/PEN/N (N###PEN/N*&*, NMN (N###MN*&*), OL50/N###OL50(**), PB-2, SM61, SM62, TK-####, TP-#### N89 200(N)
Report Date: 1999-06-03 © 2024 UL LLC
Construction Details (Table I)
Complies with IEC Publication 85
The use of this insulation system is limited to the combination of materials specified below. Where more than one item is designated under insulation function, they may be used together, unless otherwise indicated, or they may be used as alternates to one another. Functions designated "optional" are not necessarily required for every design. Insulation thicknesses and/or layers below indicated are minimum.
Filament Wire
Additional Ground & Interwinding insulation is required to separate this winding from other windings or between this winding and grounded/dead metal
Recognized Component Single and Multi-Layer Insulated Winding Wire (OBJT2) listed below
Recognized Component Appliance Wiring Material (AVLV2) listed below
Unless otherwise noted, winding wire types listed below may be used in combination within a single product
Han Kyung
AWM Style 3132constructed with R/C polyester basecoat with polyamid-imide topcoat, rated 220C
Enameled Wire
Recognized Component - Magnet wire (OBMW2), single build or greater, round or rectangular, copper or aluminum unless stated otherwise for the types listed below
Ground Insulation is required to separate this winding from grounded/dead metal
Interwinding Insulation is required to separate this winding from other enameled wire
Unless otherwise noted, Winding Wire types listed below may be used in combination within a single product
ANSI TypeTemp(°C)Basecoat(Topcoat)
MW 35or 200°CPolyester-amide-imide (Polyamide-imide)
MW 73or 200°CPolyester-amide-imide (Polyamide-imide)
MW 74or 200°CPolyester-amide-imide
Bare Conductor - Bare conductor insulated with Dupont's Nomex materials listed for Ground and Interwinding Insulation, min. thickness 2.0 mils, 50% overlap; bare conductor or PTFE lead wire insulated with Dupont's Kaladex or Quin-T Corp's CeQuin materials or silico
Ground and Interwinding Insulations
Designationmils(mm)comments
3M Innovative Paper Technologies
CeQuin 30005.0 (0.13)
3M Innovative Paper Technologies [E65069] - Recognized Component
TufQUIN 1105.0 (0.13)
BASF CORP [E36632] - Recognized Component
Petra 130(+)(f1)(t6)20.0 (0.51)
CELANESE INTERNATIONAL CORP [E41938] - Recognized Component
Rynite 530 (f1) (+), 530L (f1) (+)20.0 (0.51)
Rynite FR530(l)(+)(f1), FR530L(l)(+)(f1)20.0 (0.51)
DuPont Specialty Products USA, LLC [E34739] - Recognized Component
Nomex® 4105.0 (0.13)
Nomex® 41111.5 (0.29)
Nomex® 4145.0 (0.13)
Nomex® 416, 416 LAM5.0 (0.13)
Nomex® 418, 818, 864LAM5.0 (0.13)
Nomex® 464, 464 LAM5.0 (0.13)
Nomex® 992, 992PSB10.0 (0.25)
Nomex® 993, 993PSB8.25 (0.21)
Nomex® 994, 994PSB8.25 (0.21)
E. I. Dupont de Nemours & Co.
Nomex® 4245 (0.13)aramid insulating paper
Nomex® 4255 (0.13)aramid insulating paper
Nomex® E56A7.5 (0.19)
Fibertek
NMN3-3-3[layers]Nomex 410, 416 or 464
Mylar Specialty Films [E93687] - Recognized Component
KALADEX Kaladex 1030 *** this product is no longer Recognized *** 1.0 (0.03)
P LEO & CO LTD [E126174] - Recognized Component
1PEN2
1PEN3
1PN2R
1PN3R1.0 (0.03)
P. Leo
L/PEN/L***L Represents Polyester Film, PEN represents Kaladex film, minimum 1 mil thickness. *** represents each layer thickness in mils
N###/1P801
N###/1P802
N###/1PEN2
N###/1PN2R
N/PEN/N (N###PEN/N*&*N### represents Nomex 410,411,414,416,464,418,419, E56A. M represents Polyester Film. PEN represents Kaladex. * represents each layer thickness in mils. & - indicates any thickness of Polyester or Kaladex.
N410MICA5(0.4)N410 represents Nomex 410, thickness of 5 mils
NMN (N###MN*&*)N### represents Nomex 410,411,414,416,464,418,419, E56A. M represents Polyester Film. PEN represents Kaladex. * represents each layer thickness in mils. & - indicates any thickness of Polyester or Kaladex.
TOYOBO CO LTD [E51743] - Recognized Component
Teonex Film NQ510, Q5100, Q5300, Q8100, Q83001.0 (0.03)
Lead Wires
lead wires are optional for this system
TempInsulation
180°CSR - silicone rubber(with or without braid) +
200°CSR - silicone rubber(with or without braid)
200°CPTFE - polytetrafluoroethylene
200°CETFE - ethylene tetrafluoroethylene
200°CFEP - fluorinated ethylene propylene
220°CSR - Silicone rubber(with or without braid)
+ To be isolated from direct contact with windings (magnet wire) by any insulating material (tape, layer insulation, sleeving,etc.) listed in this table - unless specifically excluded from this requirement by a special note at the beginning of this table.
Minor Sheet Materials
(layer, outer, wrap etc.) minor sheet is optional for this system
Designationcomments
DuPont Specialty Products USA, LLC [E34739] - employing Recognized materials
Nomex® 410
Nomex® 411
Nomex® 414
Nomex® 416, 416 LAM
Nomex® 419 *** materials are no longer Recognized ***
Nomex® 464, 464 LAM
Nomex® 992, 992PSB
Nomex® 993, 993PSB
Nomex® E56, 356
E. I. Dupont de Nemours & Co.
Kaladex 2030
Kapton CR
Kapton HN
Kapton PST
Nomex® E56A
Nomex® N196
Mylar Specialty Films [E93687] - employing Recognized materials
KALADEX Kaladex 2000
P. Leo
8M81
8M82
D/PEN**** - thickness of film
DM*** - represents each layer thickness in mils.
DMD###### = layer thickness in mils
DPD###### = layer thickness in mils
L/PEN/L*&** - represents each layer thickness in mils. & - any thickness of polyester or Kaladex 2000.
N###/1N012(**)N### indicates Nomex grade 410,411,414,418,416,464,E196,E734,E56, or E56A. (**) - indicates Nomex total thickness in mils. 1N012 is a tape by P. Leo
N###/1P801(**)N### indicates Nomex grade 410,411,414,418,416,464,E196,E734,E56, or E56A. (**) - indicates Nomex total thickness in mils. 1P801 is a tape by P. Leo
N###/1P802(**)N### indicates Nomex grade 410,411,414,418,416,464,E196,E734,E56, or E56A. (**) - indicates Nomex total thickness in mils. 1P802 is a tape by P. Leo
N###/K/N*&*N### or N is Nomex 410,411,414,416,464,418,419,E56,E56A. M is Polyester Film. * - represents each layer thickness in mils. & - any thickness of polyester or Kaladex 2000.
N###/N155(**)N### indicates Nomex grade 410,411,414,418,416,464,E196,E734,E56, or E56A. (**) - indicates Nomex total thickness in mils. N155 is a tape by P. Leo
N###/OL50(**)N### indicates Nomex grade 410,411,414,418,416,464,E196,E734,E56, or E56A. (**) - indicates Nomex total thickness in mils. OL50 is UL Recognized under file MH18339
N###/PEN*&*N### or N is Nomex 410,411,414,416,464,418,419,E56,E56A. M is Polyester Film. * - represents each layer thickness in mils. & - any thickness of polyester or Kaladex 2000. PEN is Kaladex film.
N###/PEN2(**)N### indicates Nomex grade 410,411,414,418,416,464,E196,E734,E56, or E56A. (**) - indicates Nomex total thickness in mils. 1PEN2 is a tape by P. Leo
N###/PN2R(**)N### indicates Nomex grade 410,411,414,418,416,464,E196,E734,E56, or E56A. (**) - indicates Nomex total thickness in mils. PN2R is a tape by P. Leo
N###M*&N### or N is Nomex 410,411,414,416,418,419,464,E56,E56A. * - represents each layer thickness. & - thickness of polyester or Kaladex 2000.
N###MN*&*N### or N is Nomex 410,411,414,416,464,418,419,E56,E56A. M is Polyester Film. * - represents each layer thickness in mils. & - any thickness of polyester or Kaladex 2000.
N###PEN/N*&*N### or N is Nomex 410,411,414,416,464,418,419,E56,E56A. M is Polyester Film. * - represents each layer thickness in mils. & - any thickness of polyester or Kaladex 2000. PEN is Kaladex film.
OL50/N###OL50(**)N### indicates Nomex grade 410,411,414,418,416,464,E196,E734,E56, or E56A. (**) - indicates Nomex total thickness in mils. OL50 is UL Recognized under file MH18339
PB-2
SM61
SM62
TK-##### - represents thickness layer in mils
TP-##### - represents thickness layer in mils
Sung Won Electric
DMDPolyester nonwoven/plyester film/Polyester nonwoven in any combination
NTNNomex/Polyester/Nomex
VDMDVarnished DMD in any combination
any sheet insulation or tape described in this table with no minimum thickness requirement may be used as a minor sheet material
Tapes
tapes are optional for this system
Designationcomments
P Leo & Co (B C) Ltd
1K7172silicone adhesive, polyimide film
1P130acrylic adhesive, polyester film
1P800polyester film
1P808polyester film
1P830acrylic adhesive, polyester film
1P9FR
1TF07
P LEO & CO LTD [E126174] - Listed or Recognized Component
1A025
1G006
1G015
1G027A
1G130 (o)
1G155
1G180
1H818 (m)
1H850 Black (q)
1H850 Natural (o)
1H860 (f)
1H861 (f) *** this product is no longer Recognized ***
1H862 (f) *** this product is no longer Recognized ***
1H863 (f) *** this product is no longer Recognized ***
1H866 (g)
1H86A (o)
1H86R (g)
1K063
1K063CR
1K7170
1K7171A
1K7177 *** this product is no longer Recognized ***
1K7270
1N008
1N012
1N155
1P133 (f)
1P135 (c) *** this product is no longer Recognized ***
1P350 (e)
1P700 (b)
1P701 (b)
1P702 (b)
1P703
1P705
1P707 (b)
1P717 (b)
1P751
1P801
1P802
1P802 (k)
1P833 xx (@)
1PEN2
1PEN3
1PG880 (o)
1PN2R
1PN3R
1PN820 (o)
1TF05
SWECO
AGT-180adhesive, glass cloth
AKT-180
ANT-155Nomex, adhesive
Core tubes and Bobbins
(for mechanical support only) cores are optional for this system
Designationcomments
CELANESE INTERNATIONAL CORP [E41938] - employing Recognized materials
Rynite FR530(l)(+)(f1), FR530L(l)(+)(f1)
SUMITOMO BAKELITE CO LTD [E41429] - employing Recognized materials
SUMIKON PM-9630
SUMIKON PM-9750
SUMIKON PM-9820, PM-9825
SUMIKON PM-9850
Spacer and Wedges
spacer and wedges are optional for this system
Designationcomments
Glastic Corp.
FHT
MTS rod
SG-200
TSFpolyester/glass
Sun Won Electric Co Inc (SWECO)
EGL
MFGL
SWECO INC [E115870] - employing Recognized materials
SK 661
Various Manufacturers
Wood, Untreated
any material described in this table with no thickness requirement may be used as a spacer or a wedge
Tubing and Sleeving
tubing and sleeving are optional for this system
Designationcomments
P LEO & CO LTD [E176865] - Recognized Component
2T-TFL-xx.x (a)
2T-TFS-xx.x (a)
2T-TFT-xx.x (a)
P LEO & CO LTD [E195829] - Recognized Component
2R-SG# *** this product is no longer Recognized ***
P. Leo & Co Ltd
2R-YG
Stone Industries
Nomex
Sung-Won Electric Co Inc
S/Gsilicone rubber coated fiberglass
Varflex
Silicone Resin 500 H-B-1
Silicone Rubber ES 4400 H-A-1
Silicone Rubber H-B-1
Varglas H-A-1
Varglas H-C-1
Varglas Silicone Resin 500 H-A-1
Varglas Viton 231 H-A-1
Varglas Viton 231 H-C-1
VARFLEX CORP [E53690] - Recognized Component
Varglas Non-Fray H
Varglas Non-Fray HM
Varglas Non-Fray HP
Tie Cords
tie cords are optional for this system
Designationcomments
Teijin
Polyester
Toray
Polyester
Various Manufacturers
Fiberglass, unimpregnated
Western Filament
50DOF17W
DHS-1CL
DRT-45CL
DRT-45X
Poly Sleeving
Varnishes
Designationcomments
ELANTAS PDG, Inc. [E75225] - Recognized Component
468-2 (d), 468-2FC (d), 468-2-7-xxF (d), 468-2-7FC-xxF (d)(+) - May be replaced by prefix "E" and may be followed by a one to five alphanumeric suffix indicated percent of inert filler and/or color.
50(+3)(&), 50SM(+3)(&), 50VT(+3)(&), 50S(+3)(&), 50VTC(+3)(&), 5180(+3)(&), 5183(+3)(&), 5180 VT(+3)(&), ELAN-Dur 822A01(&), CORONA-Protect 828A01(&)(+3) - May be followed by XXF. Where XX designates level of inorganic filler and letter F or filler.
ELANTAS ZHUHAI CO LTD [E314793] - Recognized Component
60-60, 60-60S, 60-60VT, 60-60VT-200, 8180, 8183, 8180HV, 8183HV, 8180LV, 8183LV, 8183SW, 60-65S, 60-65SLV, 60-65S-30F, ELAN-Dur 822A03Recognized Component Varnish (OBOR2), with or without silica filled.

© 2024 UL LLC