Electrical Insulation System Components E247773
SYNFLEX ELEKTRO GMBH
AUF DEN KREUZEN 24, BLOMBERG Nordrhein-Westfalen 32825 DE
System Component System Designation System Class
F/GS, H/GS, SYNkraft VSP H3/36, SYNtherm DM, SYNtherm DMD, SYNtherm NKN, SYNtherm NKN411, SYNtherm NP/50, SYNtherm NP/80, SYNtherm NPN/130 411, SYNtherm NPN/50, SYNtherm NPN/80, SYNtherm VP, SYNtherm VPV, Synglas H 200 SYNFLEX 155-1 155(F)
Report Date: 2004-07-27 © 2024 UL LLC
alternate constructions:
An Authorization Letter is Required for Adoption of this System
Construction Details (Table I)
The use of this insulation system is limited to the combination of materials specified below. Where more than one item is designated under insulation function, they may be used together, unless otherwise indicated, or they may be used as alternates to one another. Functions designated "optional" are not necessarily required for every design. Insulation thicknesses and/or layers below indicated are minimum.
Enameled Wire
Recognized Component - Magnet wire (OBMW2), single build or greater, round or rectangular, copper or aluminum unless stated otherwise for the types listed below
Ground Insulation is required to separate this winding from grounded/dead metal
Interwinding Insulation is required to separate this winding from other enameled wire
Unless otherwise noted, Winding Wire types listed below may be used in combination within a single product
ANSI TypeTemp(°C)Basecoat(Topcoat)
MW 30or 180°CPolyester-amide-imide
MW 35or 200°CPolyester-amide-imide (Polyamide-imide)
MW 36or 200°CPolyester-amide-imide (Polyamide-imide)
MW 73or 200°CPolyester-amide-imide (Polyamide-imide)
MW 79or 155°CPolyurethane
MW 80or 155°CPolyurethane (Polyamide)
MW 82or 180°CPolyurethane
MW 83or 180°CPolyurethane (Polyamide)
Ground and Interwinding Insulations
any Recognized Component Plastic (QMFZ2), polyethylene terephthalate film (PET) 3 mils minimum
Designationmils(mm)comments
CELANESE INTERNATIONAL CORP [E41938] - Recognized Component
Rynite FR330 *** this product is no longer Recognized *** 15 (0.38)
Rynite FR51515 (0.38)
Rynite FR530(l)(+)(f1), FR530L(l)(+)(f1)15 (0.38)
DuPont Specialty Products USA, LLC [E34739] - Recognized Component
Nomex® 4103 (0.08)
Nomex® 4117 (0.18)
Nomex® 4143 (0.08)
Nomex® 416, 416 LAM3 (0.08)
Nomex® 418, 818, 864LAM3 (0.08)
Nomex® 464, 464 LAM3 (0.08)
Nomex® E56, 3564.5 (0.11)
Mylar Specialty Films [E93687] - Recognized Component
MYLAR Mylar A, AP, EL21, MO213 (0.08)
Synflex Elektro GmbH
SYNtherm DM3 (0.08)R/C QMFZ2 - Plastics PET film in the composite materials must be a minimum of 3 mils thickness.
SYNtherm DMD3 (0.08)R/C QMFZ2 - Plastics PET film in the composite materials must be a minimum of 3 mils thickness.
SYNtherm NKN3 (0.08)The total Nomex 410, 414, 416, 418 or 464 in the composite materials must be a minimum of 3 mils thickness.
SYNtherm NKN4117 (0.18)The total Nomex 411 in the composite materials must be a minimum of 7 mils thickness.
SYNtherm NP/803 (0.08)The total Nomex 410, 414, 416, 418 or 464 or R/C QMFZ2 - Plastics PET film in the composite materials must be a minimum of 3 mils thickness.
SYNtherm NPN/130 4117 (0.18)The total Nomex 411 in the composite materials material must be a niminum of 7 mils thickness or the R/C QMFZ2 - Plastics PET film in the composite materials must be a minimum of 3 mils thickness.
SYNtherm NPN/503 (0.08)The total Nomex 410, 414, 416, 418 or 464 or R/C QMFZ2 - Plastics PET film in the composite materials must be a minimum of 3 mils thickness.
SYNtherm NPN/803 (0.08)The total Nomex 410, 414, 416, 418 or 464 or R/C QMFZ2 - Plastics PET film in the composite materials must be a minimum of 3 mils thickness.
Lead Wires
lead wires are optional for this system
TempInsulation
125°CXLPE - crosslinked polyethylene +
150°CXLPE - crosslinked polyethylene
150°CXLPO - crosslinked polyolefin
+ To be isolated from direct contact with windings (magnet wire) by any insulating material (tape, layer insulation, sleeving,etc.) listed in this table - unless specifically excluded from this requirement by a special note at the beginning of this table.
Minor Sheet Materials
(layer, outer, wrap etc.) minor sheet is optional for this system
Designationcomments
Synflex Elektro GmbH & Co. KG
SYNkraft VSP H3/36
SYNtherm DM
SYNtherm DMD
SYNtherm NKN
SYNtherm NKN411
SYNtherm NP/50
SYNtherm NP/80
SYNtherm NPN/130 411
SYNtherm NPN/50
SYNtherm NPN/80
SYNtherm VP
SYNtherm VPV
TOYOBO CO LTD [E51743] - employing Recognized materials
Teonex Film NQ510, Q5100, Q5300, Q8100, Q8300
any sheet insulation or tape described in this table with no minimum thickness requirement may be used as a minor sheet material
Tapes
tapes are optional for this system
Designationcomments
3M COMPANY [E17385] - Listed or Recognized Component
1350-1 (b)
1350-2 (c)
1350T-1 (b)
1350T-2 (b)
1350T-3 (b)
27 (a)
79
Synflex Elektro GmbH
SynTape B 616/ GL.95
SYNFLEX ELEKTRO GMBH [E301705] - Listed or Recognized Component
B564
Synflex Elektro GmbH & Co. KG
Syntape B 107/11B
Syntape B 107/P31
Syntape B 108/9B
Syntape B 113/P34
Syntape B/12B
Syntape B/41B
Syntape B/P355
Syntape B/P42
Syntape B/PR25
Syntape B/PT25
Syntape B/PT45
Syntape B113/10B
Syntape B354/180B
Syntape F /PX50)
Syntape F 366/ 19F
Syntape F 562/77AH
Syntape F 562/GL94
Syntape F/5H
Syntape F/H50AC
Syntape F/K30AC
Syntape F/PS25
Syntape F/PT2020
Syntape F/X50
Syntape F/X80
Syntape F118/70AC
Syntape F118/H20AC
Syntape F131/PT40
Syntape H 618/GL96
Syntape H/H50
Syntape H/K30
Syntape H428/71SL
Syntape H428/H20
Tubing and Sleeving
tubing and sleeving are optional for this system
Designationcomments
Synflex Elektro GmbH & Co. KG
F/GS
H/GS
Tie Cords
tie cords are optional for this system
Designationcomments
F. A. Schurig GmbH & Co. KG
Polyesterschrumpfband
Synflex Elektro GmbH & Co. KG
Synglas H 200
Varnishes
varnishes are optional for this system
Designationcomments
Axalta Coating Systems Germany GmbH & Co.KG [E101752] - Recognized Component
Voltatex 4010, Voltatex 4011, Voltabas 0105May not be used with magnet wire ANSI types MW79, MW80, MW82 and MW83.
Voltatex 4110May not be used with magnet wire ANSI types MW79, MW80, MW82 and MW83
Voltatex 4200, Voltatex 4201, Voltatex 4220, Voltatex 4230, Voltatex 4250, Voltatex 4250 S, Voltatex 4251, Voltatex 4260
John C Dolph Co [E317427] - Recognized Component
CC-1105, CC-1105HTC, CC-1103, CC-1105OPT, CC-1105OPT/HTC, CC-1105LV, CB-1105HTC, PDR-1933, PDR-1711, CC-1155, CC-1156, CC-1106May not be used with magnet wire ANSI type MW30, MW79, MW80, MW82 and MW83.
XL-2102, XL-2102OPT, XL-2101, XL-2101T, XL-2101OPT, XL-2103, XL-2103LV, XL-2104, XL-2105, XL-2106, XL-2107, XL-2108, XL-2109May not be used with magnet wire ANSI type MW30

© 2024 UL LLC