Comparative Tracking Index (CTI): | 0 | Inclined Plane Tracking (IPT) kV: | - |
Dielectric Strength (kV/mm): | - | Volume Resistivity (10x ohm-cm): | - |
High-Voltage Arc Tracking Rate (HVTR): | - | Surface Resistivity (10x ohms/square): | - |
Dimensional Change (%): | - | High Volt, Low Current Arc Resis (D495): | - |
RoHS 2011/65/EU & 2015/863 Compliant Material (color: NC) | view certificate |
UL 746H Non-Chlorine & Non-Bromine Material (color: NC) | |
IEC and ISO Test Methods |
Test Name | Test Method | Units | Thk (mm) | Value |
Flammability | IEC 60695-11-10 | Class (color) | 2.4 | HB, HB75 (NC) |
| | | 4.0 | HB, HB40 (NC) |
Glow-Wire Flammability (GWFI) | IEC 60695-2-12 | °C | - | - |
Glow-Wire Ignition (GWIT) | IEC 60695-2-13 | °C | - | - |
IEC Comparative Tracking Index | IEC 60112 | Volts (Max) | - | - |
IEC AC Dielectric Strength (AC DS) | IEC 60243-1 | kV/mm | - | - |
IEC DC Dielectric Strength (DC DS) | IEC 60243-2 | kV/mm | - | - |
IEC Volume Resistivity (VR) | IEC 62631-3-1 | 10x ohm-m | - | - |
IEC Surface Resistivity (SR) | IEC 62631-3-2 | 10x ohms | - | - |
IEC Inclined Plane Tracking (IPT) | IEC 60587 | kV | - | - |
IEC Ball Pressure | IEC 60695-10-2 | °C | - | - |
ISO Heat Deflection (1.80 MPa) | ISO 75-2 | °C | - | - |
ISO Tensile Strength | ISO 527-2 | MPa | - | - |
ISO Flexural Strength | ISO 178 | MPa | - | - |
ISO Tensile Impact | ISO 8256 | kJ/m2 | - | - |
ISO Izod Impact | ISO 180 | kJ/m2 | - | - |
ISO Charpy Impact | ISO 179-1 | kJ/m2 | - | - |