UL
iQ
for Surge Protective Devices
Surge Protective Devices
E326289
Guide Information
Citel America Inc
10108 USA Today Way, Miramar FL 33025
Model(s): CAD2-120S-WX-Y-Z (b)
Permanently Connected
SPD
Type
Volts
(V)
AC/DC
DC PV
Phase
Amps
(A)
Ambient
Min(°C)
Ambient
Max(°C)
Mode
VPR
(Vpk)
MCOV
(V)
In
(kA)
SCCR
(kA)
1
120
AC
1
n/a
-35
60
L-N
1200
300
20
100
L-G
800
150
N-G
700
150
Evaluated to: UL 1449 5th Ed. Rev: 2021-01-08
(b) -
Where W can be 1 or 2, X can be 6, 12, 24, 48 or 170, Y can be H or W, Z can be I or A.
SPDs investigated for Type 1 applications are automatically suitable for Type 2 applications and may be marked for SPD Type 1 and/or Type 2 applications. SPDs only marked "SPD Type 2" are not suitable for Type 1 applications.
Where a minimum ambient temperature is not specified, assume 0°C unless the product is marked otherwise or with an Outdoor use Environmental Rating. See Electrical Equipment for Use in Ordinary Locations (AALZ) for details regarding Environmental Ratings.
Report Date:
2012-09-21
© 2024 UL Solutions
Last Revised:
2021-09-30