Component - PlasticsE107854
Guide Information
CELANESE INTERNATIONAL CORP
FORTRON BUSINESS LINE, 8040 DIXIE HWY, FLORENCE KY 41042
1140L4(g), MT9140L4(g)
Polyphenylene Sulfide (PPS) "Fortron", furnished as pellets

Color
Min. Thk
(mm)
Flame
Class

HWI

HAI
RTI Elec
(°C)
RTI Imp
(°C)
RTI Str
(°C)
ALL0.38V-0-0130180200
0.81V-030220200200
1.5V-010220200220
3.0V-0;5VA10220200220
Comparative Tracking Index (CTI):4Inclined Plane Tracking (IPT) kV:-
Dielectric Strength (kV/mm):-Volume Resistivity (10x ohm-cm):3
High-Voltage Arc Tracking Rate (HVTR):-Surface Resistivity (10x ohms/square):-
Dimensional Change (%):-High Volt, Low Current Arc Resis (D495):-
RoHS 2011/65/EU & 2015/863 Compliant Material (color: ALL)view certificate
(g) - May be followed by DW
ANSI/UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. ANSI/UL 94 small-scale test data is intended solely for determining the flammability of plastic materials used in the components and parts of end-product devices and appliances, where the acceptability of the combination is determined by UL.
© 2026 UL Solutions
Last Revised:2026-08-14