iq.ul.com
CLICK TO CONTINUEView additional material information including performance and processing data The information presented on the UL Prospector datasheet was acquired by UL Prospector from the producer of the material. UL Prospector makes substantial efforts to assure the accuracy of this data. However, UL Prospector assumes no responsibility for the data values and strongly encourages that upon final material selection, data points are validated with the material supplier.
Component - PlasticsE41938
Guide InformationView Certificate of Compliance
CELANESE INTERNATIONAL CORP
8040 DIXIE HWY, FLORENCE KY 41042-2904
FR530(l)(+)(f1), FR530L(l)(+)(f1)
Polyethylene Terephthalate (PET), glass reinforced, flame retardant "Rynite", furnished as pellets [contains mechanically recycled content]
Attention Materials Users! This product Certification has been changed on 2023-02-16; UL94 Flame class has been revised click here to learn more

Color
Min. Thk
(mm)
Flame
Class

HWI

HAI
RTI Elec
(°C)
RTI Imp
(°C)
RTI Str
(°C)
NC, BK0.35V-031155155155
ALL0.75V-021155155155
NC, BK1.5V-0, 5VA01155155155
ALL2.0V-0, 5VA01155155155
3.0V-0, 5VA01155155155
Comparative Tracking Index (CTI):2Inclined Plane Tracking (IPT) kV:-
Dielectric Strength (kV/mm):34Volume Resistivity (10x ohm-cm):16
High-Voltage Arc Tracking Rate (HVTR):1Surface Resistivity (10x ohms/square):-
Dimensional Change (%):0High Volt, Low Current Arc Resis (D495):6
(+) - Virgin and regrind up to 50% by weight inclusive, have the same basic material characteristics.
(f1) - Suitable for outdoor use with respect to exposure to Ultraviolet Light, Water Exposure and Immersion in accordance with UL 746C.
(l) - Recognized ground insulation component at 0.4 mm with MW79 in UL1446 Class 155 electrical insulation system designated R201N (File E69939).
NOTE - (1) Material designations that are color pigmented may be followed by suffix letters and numbers. (2) Material designations may be prefixed by "ZYT" for Zytel or "MIN" for Minlon or "CRA" for Crastin or "RYN" for Rynite.
ANSI/UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. ANSI/UL 94 small-scale test data is intended solely for determining the flammability of plastic materials used in the components and parts of end-product devices and appliances, where the acceptability of the combination is determined by UL.
Report Date:1996-01-04© 2024 UL Solutions
Last Revised:2023-02-17
 
IEC and ISO Test Methods
Test NameTest MethodUnitsThk (mm)Value
FlammabilityIEC 60695-11-10, IEC 60695-11-20Class (color)0.35V-0 (NC, BK)
0.75V-0 (ALL)
1.5V-0, 5VA (NC, BK)
2.0V-0, 5VA (ALL)
3.0V-0, 5VA (ALL)
Glow-Wire Flammability (GWFI)IEC 60695-2-12°C0.75960
1.5960
2.0960
3.0960
Glow-Wire Ignition (GWIT)IEC 60695-2-13°C0.75800
1.5800
2.0985
3.0985
IEC Comparative Tracking IndexIEC 60112Volts (Max)--
IEC AC Dielectric Strength (AC DS)IEC 60243-1kV/mm--
IEC DC Dielectric Strength (DC DS) IEC 60243-2kV/mm--
IEC Volume Resistivity (VR)IEC 62631-3-110x ohm-m--
IEC Surface Resistivity (SR)IEC 62631-3-210x ohms--
IEC Inclined Plane Tracking (IPT)IEC 60587kV--
IEC Ball PressureIEC 60695-10-2°C-245
ISO Heat Deflection (1.80 MPa)ISO 75-2°C--
ISO Tensile StrengthISO 527-2MPa--
ISO Flexural StrengthISO 178MPa--
ISO Tensile ImpactISO 8256kJ/m2--
ISO Izod ImpactISO 180kJ/m2--
ISO Charpy ImpactISO 179-1kJ/m2--