iq.ul.com
CLICK TO CONTINUEView additional material information including performance and processing data The information presented on the UL Prospector datasheet was acquired by UL Prospector from the producer of the material. UL Prospector makes substantial efforts to assure the accuracy of this data. However, UL Prospector assumes no responsibility for the data values and strongly encourages that upon final material selection, data points are validated with the material supplier.
Component - PlasticsE207780
Guide InformationView Certificate of Compliance
SABIC JAPAN L L C
PACIFIC GRADES - RESIN, 2-2 KINUGAOKA, MOKA-SHI TOCHIGI-KEN 321-4392 JP
EXL1132T
PC/Siloxane, UV Stabilized "Lexan, ELCRES", furnished as pellets

Color
Min. Thk
(mm)
Flame
Class

HWI

HAI
RTI Elec
(°C)
RTI Imp
(°C)
RTI Str
(°C)
ALL0.7HB--808080
0.8HB--808080
1.5HB--130120130
3.0HB--130120130
Comparative Tracking Index (CTI):-Inclined Plane Tracking (IPT) kV:-
Dielectric Strength (kV/mm):-Volume Resistivity (10x ohm-cm):-
High-Voltage Arc Tracking Rate (HVTR):-Surface Resistivity (10x ohms/square):-
Dimensional Change (%):-High Volt, Low Current Arc Resis (D495):-
NOTE - Material designation may be followed by a color nomenclature consisting of either an alpha/numeric or numeric/alpha combination.
ANSI/UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. ANSI/UL 94 small-scale test data is intended solely for determining the flammability of plastic materials used in the components and parts of end-product devices and appliances, where the acceptability of the combination is determined by UL.
Report Date:2002-08-15© 2024 UL Solutions
Last Revised:2022-12-08
 
IEC and ISO Test Methods
Test NameTest MethodUnitsThk (mm)Value
FlammabilityIEC 60695-11-10Class (color)0.7HB, HB75 (ALL)
0.8HB, HB75 (ALL)
1.5HB, HB75 (ALL)
3.0HB, HB40 (ALL)
Glow-Wire Flammability (GWFI)IEC 60695-2-12°C0.8825
1.5825
3.0960
Glow-Wire Ignition (GWIT)IEC 60695-2-13°C0.8850
1.5850
3.0850
IEC Comparative Tracking IndexIEC 60112Volts (Max)--
IEC AC Dielectric Strength (AC DS)IEC 60243-1kV/mm--
IEC DC Dielectric Strength (DC DS) IEC 60243-2kV/mm--
IEC Volume Resistivity (VR)IEC 62631-3-110x ohm-m--
IEC Surface Resistivity (SR)IEC 62631-3-210x ohms--
IEC Inclined Plane Tracking (IPT)IEC 60587kV--
IEC Ball PressureIEC 60695-10-2°C--
ISO Heat Deflection (1.80 MPa)ISO 75-2°C--
ISO Tensile StrengthISO 527-2MPa--
ISO Flexural StrengthISO 178MPa--
ISO Tensile ImpactISO 8256kJ/m2--
ISO Izod ImpactISO 180kJ/m2--
ISO Charpy ImpactISO 179-1kJ/m2--